HEATING RATINGS FRAUD

FABRICATED COP, COP2, HSPF2, AND HEATING CAPACITIES

Copycat brands fake heating performance exactly the way they fake cooling performance. They publish heating capacities, COP, COP2 values, and HSPF2 ratings that contradict basic thermodynamics, AHRI 210/240 test behavior, DOE and NRCan classifications, and their own watt inputs. A single hardware platform cannot legitimately produce multiple heating capacities, COP values, and HSPF2 results depending on which sticker is applied to the front panel, especially when the efficiencies are similar. These inconsistencies do not come from a laboratory; they come from a spreadsheet.

 

The same Nordica machine, with the identical compressor, coil surface area, refrigerant charge, airflow system, motor, electronics, and chassis geometry, is advertised with a heating output ranging from 8,000 to 11,970 BTU. Ice Air claims 8,000 BTU; Islandaire claims 9,000 BTU; Applied Comfort, PMC Green, and Nordica claim 10,000 BTU; DesignLine claims 11,200 BTU. There is no physical basis for a 50%+ variation in heating capacity unless the hardware changes. It does not. Every capacity value above the lowest real number is fabricated.

The COP, COP2, and HSPF2 values are even more revealing. Under AHRI 210/240, inverter heat pump efficiency follows a predictable pattern: lower-capacity units produce higher COP, and higher-capacity units produce lower COP. The copycat ratings show the opposite, claiming that higher heating capacity comes with equal or even higher COP. This outcome is impossible for this coil size, compressor, and airflow configuration. These contradictions alone prove that the data were not measured in a lab but simply invented.

Direct math exposes the fraud:

The most conclusive proof is the comparison between Ice Air’s 8,000 BTU at 3.5 COP and DesignLine’s 11,200 BTU at the same 3.5 COP — a 40% increase in heating output with no efficiency loss and no increase in wattage. A heat pump cannot increase its heating capacity by 40% without a larger compressor, larger coils, a different refrigerant, higher airflow, higher input power, a different metering device, and revised firmware. None of these changes were made. A reseller cannot outperform the manufacturer’s already-inflated ratings without replacing the hardware. No such redesign exists. The numbers are fabricated.

The fraud becomes undeniable when the data is organized. The tables below sort ratings and capacities in different orders to expose the scam. In real-world data, capacity and efficiency are related. Here, there is no relationship whatsoever.

Sorted by Capacity

Capacity and efficiency are related in real-world data. Of course, there is no relationship whatsoever here.

Nordica Units

Brand Model Voltage Rated Capacity Rated Power
Ice Air 8RSXC09-DH 208V 8,000 670
Nordica YWD-10HD/FC6-W 115V 9,000 930
Nordica YWD-10HD2/FC6-W 208/230V 9,000 850
Applied Comfort Coolflow32 TPHE10L00E6 115V 10,000 810
Applied Comfort Coolflow32 TPHE10K10E6 208-230V 10,000 810
Dubbll DDHPA-10X-00E 115V 9,000 818
Dubbll DDHPA-12Y-10E 230V 9,000 818
PMC Green PMCG-10HD 115V 10,000 920
DesignLine Roommate MHP10 115V 11,200 938
DesignLine Roommate MHP11 230V 11,200 938
swipe to see more

Zymbo Clima Puro Units

Brand Model Voltage Rated Capacity Rated Power
Zymbo Clima Puro 207-251V 8,800 700
Williams Montara 208-230V 8,000 720
Silktech EcoAuro 1.0 207-251V 8,000 700
swipe to see more

Zymbo Dolphin 40 Units

Brand Model Voltage Rated Capacity Rated Power
Zymbo Dolphin 40 208-230V 11,970 947
Ortech Solo 208/230V 11,970 947
Genuine Comfort GCMB-H12KA0-1 208V 11,970 947
Genuine Comfort GCMB-H12KC2-1 208V 11,970 947
Genuine Comfort GCMB-H12KD3-1 208V 11,970 947
Waysos Compact-Aire 3K 208V 11,970 1,209
Mits Air MITSWZ-40EC 208/230V 11,970 947
Silktech EcoAuro 2.0 208-230V 11,970 1,100
Kinghome Dolphin 40 208-230V 11,970 947
swipe to see more

Wuxi Hammer Units

Brand Model Voltage Rated Capacity Rated Power
Inspiron Air iAIRHP-35-WM-A 207-251V 11,500 1,050
Multi MFG MAIRHP-35-WM 208-230V 9,400 810
swipe to see more

Sorted by Efficiency

If the data were real, more efficient units would have a lower capacity. Here, where fake data rules, higher-capacity units are more efficient. Note that this table ignores the brand’s efficiency rating and instead uses the calculated efficiency based on the capacity and wattage input they claim.

Nordica Units

Brand Model Voltage Rated Capacity Rated Power Calculated COP
Dubbll DDHPA-10X-00E 115V 9,000 818 3.22
Dubbll DDHPA-12Y-10E 230V 9,000 818 3.22
Applied Comfort Coolflow32 TPHE10L00E6 115V 10,000 810 3.62
Applied Comfort Coolflow32 TPHE10K10E6 208-230V 10,000 810 3.62
Ice Air 8RSXC09-DH 208V 8,000 670 3.50
DesignLine Roommate MHP10 115V 11,200 938 3.50
DesignLine Roommate MHP11 230V 11,200 938 3.50
PMC Green PMCG-10HD 115V 10,000 920 3.19
Nordica YWD-10HD2/FC6-W 208/230V 9,000 850 3.10
IslandAire EZMB10L5A1S95AA 115V 9,000 930 2.84
Nordica YWD-10HD/FC6-W 115V 9,000 930 2.84
swipe to see more

Zymbo Clima Puro Units

Brand Model Voltage Rated Capacity Rated Power Calculated COP
Zymbo Clima Puro 207-251V 8,800 700 3.68
Silktech EcoAuro 1.0 207-251V 8,000 700 3.35
Williams Montara 208-230V 8,000 720 3.26
swipe to see more

Zymbo Dolphin 40 Units

Brand Model Voltage Rated Capacity Rated Power Calculated COP
Ortech Solo 208/230V 11,970 947 3.70
Mits Air MITSWZ-40EC 208/230V 11,970 947 3.70
Genuine Comfort GCMB-H12KA0-1 208V 11,970 947 3.70
Genuine Comfort GCMB-H12KC2-1 208V 11,970 947 3.70
Genuine Comfort GCMB-H12KD3-1 208V 11,970 947 3.70
Zymbo Dolphin 40 208-230V 11,970 947 3.70
Waysos Compact-Aire 3K 208V 11,970 1,209 3.70
Kinghome Dolphin 40 208-230V 11,970 947 3.70
Silktech EcoAuro 2.0 207-251V 11,970 1,100 3.48
swipe to see more

Wuxi Hammer Units

Brand Model Voltage Rated Capacity Rated Power Calculated COP
Multi MFG MAIRHP-35-WM 208-230V 9,400 810 3.40
Inspiron Air iAIRHP-35-WM-A 207-251V 11,500 1,050 3.21
swipe to see more

Calculated COP Compared to Published COP

Here, you can see that almost none of the COP’s claims align with calculations based on the brands’ published data. Once again, it’s hard to overstate how sloppy these fabricated numbers are!

Nordica Units

Brand Model Voltage Rated Capacity Rated Power Calculated COP Published COP
Applied Comfort Coolflow32 TPHE10L00E6 115V 10,000 810 3.62 3.20
Applied Comfort Coolflow32 TPHE10K10E6 208-230V 10,000 810 3.62 3.20
Dubbll DDHPA-10X-00E 115V 9,000 818 3.22 3.23
Dubbll DDHPA-12Y-10E 230V 9,000 818 3.22 3.23
DesignLine Roommate MHP10 115V 11,200 938 3.50 3.50
DesignLine Roommate MHP11 230V 11,200 938 3.50 3.50
PMC Green PMCG-10HD 115V 10,000 920 3.19 3.19
Nordica YWD-10HD2/FC6-W 208/230V 9,000 850 3.10 3.40
IslandAire EZMB9L5A1S95AA 230V 9,000 850 3.10 3.40
IslandAire EZMB10L5A1S95AA 115V 9,000 930 2.84 3.40
Nordica YWD-10HD/FC6-W 115V 9,000 930 2.84 3.10
swipe to see more

Zymbo Clima Puro Units

Brand Model Voltage Rated Capacity Rated Power Calculated COP Published COP
Zymbo Clima Puro 208-230V 8,800 700 3.68 3.35
Williams Montara 208-230V 8,000 720 3.26 3.20
Silktech EcoAuro 1.0 208-230V 8,000 700 3.35 3.40
swipe to see more

Zymbo Dolphin 40 Units

Brand Model Voltage Rated Capacity Rated Power Calculated COP Published COP
Zymbo Dolphin 40 208-230V 11,970 947 3.70 3.50
Ortech Solo 208/230V 12,030 947 3.72 N/A
Genuine Comfort GCMB-H12KA0-1 208-230V 11,970 947 3.70 N/A
Genuine Comfort GCMB-H12KC2-1 208V 11,970 947 3.70 N/A
Genuine Comfort GCMB-H12KD3-1 208V 11,970 947 3.70 N/A
Mits Air MITSWZ-40EC 208/230V 11,970 947 3.70 N/A
Waysos Compact-Aire 3K 208V 11,970 1,209 2.90 3.50
Silktech EcoAuro 2.0 208-230V 11,970 1,100 3.47 3.66
Kinghome Dolphin 40 208-230V 11,970 947 3.70 3.50
swipe to see more

Wuxi Hammer Units

Brand Model Voltage Rated Capacity Rated Power Calculated COP Published COP
Multi MFG MAIRHP-35-WM 208-230V 9,400 810 3.40 3.40
Inspiron Air iAIRHP-35-WM-A 207-251V 11,500 1,050 3.21 3.45
swipe to see more

HSPF2 Compare

The three brands that publish an HSPF2 all conflict with the data. Does it make sense that Zymbo manufactures the units for Silktech and Ortech, yet Silktech claims a 6.7 HSPF2 at 8,800 BTU and Ortech has a higher HSPF2 with a higher capacity? Odd as well that Dubbll claims the same HSPF2 as Nordica, which makes Dubbll’s unit, yet somehow uses less power. These numbers defy basic thermodynamics.

Nordica Units

Brand Model Voltage Rated Capacity Rated Power Calculated COP HSPF2
Nordica YWD-10HD/FC6-W 115V 9,000 930 2.84 7.50
Nordica YWD-10HD2/FC6-W 208/230V 9,000 850 3.10 7.50
Dubbll DDHPA-10X-00E 115V 9,000 818 3.22 7.50
Dubbll DDHPA-12Y-10E 230V 9,000 818 3.22 7.50
swipe to see more

Zymbo Clima Puro Units

Brand Model Voltage Rated Capacity Rated Power Calculated COP HSPF2
Silktech EcoAuro 1.0 208-230V 8,800* 700 3.68 6.70
swipe to see more

* 8,800 BTU refers to listing in the MAEDBS site, brochure lists 8,000.

Dolphin 40 Units

Brand Model Voltage Rated Capacity Rated Power Calculated COP HSPF2
Waysos Compact-Aire 3K 208V 11,970 1,209 2.90 8.20
Silktech EcoAuro 2.0 208-230V 11,970 1,100 3.47 8.20
Genuine Comfort GCMB-H12KA0-1 208V 11,970 947 3.70 8.20
Genuine Comfort GCMB-H12KC2-1 208V 11,970 947 3.70 8.20
Genuine Comfort GCMB-H12KD3-1 208V 11,970 947 3.70 8.20
Ortech Solo 208/230V 11,970 947 3.70 8.29
swipe to see more

Every heating rating published by these brands violates 10 C.F.R. § 430.2, the Energy Efficiency Regulations, AHRI 210/240 heating test requirements, ASHRAE 37 procedures, the FTC Act § 5, and the Competition Act (R.S.C., 1985, c. C-34) prohibitions on false representations, and both 10 C.F.R. Part 431 Table 7 and CSA C744 Table 7 for products falsely labeled as PTHPs. No copycat brand has a valid AHRI heating certification, a valid NRTL or SCC-Accredited Certification Body heating test report, consistent heating data across revisions, or any published numbers that match the OEM’s actual performance.

Heating performance claims across these brands are contradictory, mathematically and physically impossible, legally non-compliant, unsupported by any certified data, incompatible with DOE and NRCan classification rules, and in violation of AHRI 210/240, FTC law, and the Competition Bureau. A single unit cannot legitimately possess different heating capacities, multiple conflicting COP values, multiple inconsistent HSPF2 ratings, contradictory watt inputs, or identical COP at radically different BTUs. The contradictions prove intentional fabrication.

Ice Air Responded!

Read our response to Ice Air’s threatening letter, where we set the record straight.